Re: after failover? - Mailing list pgsql-admin

From Simon Riggs
Subject Re: after failover?
Date
Msg-id CA+U5nMJpVn0tCohUTroVJRusxiZFoL4yucsSZTES83928aH67g@mail.gmail.com
Whole thread Raw
In response to after failover?  (Ray Stell <stellr@cns.vt.edu>)
Responses Re: after failover?
List pgsql-admin
On Fri, Oct 14, 2011 at 3:02 PM, Ray Stell <stellr@cns.vt.edu> wrote:

> The tutorial here excludes an important issue:
> http://wiki.postgresql.org/wiki/Binary_Replication_Tutorial#Failing_Over_To_The_Standby
> After the failover is complete, it seems like a restart is required to
> make the new primary capable of supporting a new hot standby.  Can the
> config values be changed without an interuption of service?  I'm using
> a hotstandby config in 9.0.x.  Anything different in this regard in 9.1?
> Thanks.

There's no reason not to have  wal_level = hot_standby on the standby also.

--
 Simon Riggs                   http://www.2ndQuadrant.com/
 PostgreSQL Development, 24x7 Support, Training & Services